Technical Information
ALL RADIANT HEAT BURNER SYSTEMS™ MUST BE INSTALLED IN ACCORDANCE WITH ALL LOCAL, STATE, AND FEDERAL CODES. SOME STATES REQUIRE A LICENSED PLUMBER, LICENSED GAS FITTER, OR IN SOME LOCALITIES A QUALIFIED SERVICE TECHNICIAN TO INSTALL GAS LOG SYSTEMS. CHECK YOUR LOCAL CODES AND LAWS BEFORE INSTALLITION.
For safety purposes all Radiant Heat Burner Systems™ must be installed in a "Class A", fully-vented, solid-fuel burning fireplace constructed of noncombustible materials. Our gas logs systems are for natural gas and liquid propane residential and commercial fireplaces.
|
Log Size
|
Front Width of Fire Box Opening* | Gas Log Set Dimensions (Front/Bck/Depth |
Natural Gas BTUs | Propane Gas BTUs |
|
18"
|
24 1/2" TO 30" | 18" 15" 16" | 72,000 | 59,000 |
| 24" | 28 1/2" TO 42" | 24" 20" 18" | 95,000 | 71,000 |
| 30" |
34" TO 46"
|
30" 24" 18" | 125,000 | 100,000 |
| 36" | 46" TO 51" | 36" 30" 22" | 140,000 | 110,000 |